The dosing, and the kit that checks it.

At thirty-plus bathers a day, water chemistry stops being a routine and becomes a compliance question. Automatic dosing holds pH and chlorine steady through changing load and records what it did. Independent testing proves it. Both are here.

It is one stage of a loop

A controller cannot correct a blocked filter, failed circulation or a pool carrying more people than it was built for. It will keep dosing into a system that is not working and report that it is doing its job. Dosing belongs on top of adequate circulation, turnover and filtration, not instead of them. We will not quote dosing without filtration on the same system.

What the controller does

  • Continuous pH and ORP measurement, with peristaltic dosing of pH correction and chlorine at an adjustable rate.
  • Cloud connected, so readings, alarms and dosing history are available remotely rather than only on the panel.
  • A dosing record you can produce on request, which is what an inspector asks for and what a spreadsheet filled in afterwards is not.
  • Three 4-20mA outputs for pH, ORP and temperature, if the site runs a building management system or a chart recorder.
  • A startup mode that doses towards setpoint for up to twelve hours and stops on its own, for refills and reopenings.
  • The probes fit in-line into existing pipework, so it retrofits to a system that is already running.

Supply, or supply and install

Buy the controller on its own if you have someone competent to plumb and commission it into an existing circulation loop. Add installation and we fit it, calibrate the probes, set the dosing rates for your bather load and hand over with the system running.

Commercial water treatment

Five stages, one engineered loop.

Every Odyssey commercial installation is designed around a complete water-treatment loop. Surface skimming, filtration, UV disinfection, automatic dosing and level management working together, not a plunge with add-ons bolted onto the side.

Circulation loop

  1. Cold plunge
  2. Surface skimmer
  3. Media filter
  4. UV-C treatment
  5. Auto dosing
  6. Commercial chiller
  7. Return
01

Surface Skimming

First-line contamination control

Every commercial system incorporates a surface skimmer that continuously draws water from the top of the plunge where floating contamination accumulates: hair, body oils, cosmetic residues, surface debris. Skimming is the first stage of the treatment loop; catching contaminants at the surface reduces the load on filtration and disinfection downstream.

02

Media Filtration

Continuous suspended-particulate removal

High-rate media filtration sits at the heart of the circulation loop, continuously removing suspended contamination from the water. Filter sizing is determined during detailed design based on plunge water volume, target circulation rate, pipework resistance, plant location and expected commercial bather load.

03

UV-C Water Treatment

Secondary disinfection barrier

UV-C secondary disinfection sits alongside primary residual sanitisation. Water passes through the UV chamber during circulation, providing continuous microbial control that reduces reliance on chemical disinfection alone. No additional chemicals are introduced; the UV unit is installed accessibly for routine lamp inspection and replacement.

04

Automatic Chemical Dosing

pH + ORP monitored and corrected continuously

Commercial systems can be specified with continuous pH and Oxidation-Reduction Potential (ORP) monitoring driving automatic dosing of pH correction and chlorine-based disinfectant. Free chlorine residual is verified independently, giving the operator confirmation the required disinfectant concentration is being held under varying bather load, with far less manual intervention than a residential system.

05

Automatic Water Top-Up

Consistent operating level, hands-off

Commercial systems lose water through splash-out, evaporation and drain-down over the operating cycle. Automatic level management introduces protected replacement water to maintain the required operating depth without operator intervention. Requires a protected mains water connection with appropriate backflow protection, confirmed during detailed design.

Systems are specified against each project's bather load, operating temperature, plant space and site services. Final equipment selection is confirmed during detailed design.

A note on compliance

Automatic dosing supports PWTAG guidance rather than satisfying it. Compliance is holistic: circulation, turnover, filtration, residual, pH, testing, bathing load and procedures. We will help you spec the whole package for your site rather than selling you a box and calling it done.

Talk to our commercial team

Planning a commercial installation?

We'll help you specify the right system, plan for long-term maintenance, and ensure your investment delivers for years to come.